Reed Switch Electric Contact Pressure Gauge
Application
The pressure gauge is suitable for measuring the pressure of non- crystalline, non-solidified and non-explosive media. It is used in conjunction with electrical devices (such as relay, contactor, PLC, etc.) to pre-set the maximum or minimum pressure value and achieve automatic control and signal (alarm) purposes for the controlled system. It has measurement and control functions, and the upper and lower limits of the controlled pressure can be set according to needs. It is widely used in petroleum, chemical, power station, metallurgy, water supply and other industries, as well as electromechanical equipment.
Features
Reed switch electric contact pressure gauge can transmit signals well under low voltage (24V, 12V) without arcing phenomena. It has fast response speed and long service life. Its advantage is that the contact switch is isolated from the atmosphere, and there is noble gas or vacuum state in the tube, which can reduce the oxidation and carbonization of the contact. The sealed design can prevent external steam and dust impurities from corroding the contact. The reed switch.
Parameters
Diameter: φ100mm,φ150mm
Accuracy: 1.6%
Working Pressure:
- Steady: 3/4 X full scale value
- Fluctuating: 2/3 x full scale value
- Short Time: Full scale value
Maximum power: 10W
Working voltage: DC24V
Working Current: not more than 0.5A
Service Life: 1 million times
Control Method: Upper and lower limits
Connection Thread: M20x1.5, PF(PT,NPT)1/2, etc.
Elastic element: Qsn8-0.3 brass I SUS304 I SUS316L
Connection Material: HPb59-1 brass I SUS304 I SUS316
Movement: Brass | SUS304
Case: SUS304 / CR1 steel sheet
Window: PC glass
Operation
■The wiring operation should be carried out by a qualified electrician.
■When debugging or switching the control section, the control circuit should be disconnected, and the power can be turned on after the operation is completed.
■Reed switch electric contact pressure gauge must be used in a low voltage control environment within the specified technical range. Otherwise it will cause contact damage.
■Please read the instructions carefully before use.
■It is necessary to add a protective device for the pressure gauge in an environment with a sharp pressure change or vibration or pulsation.
■When installing or disassembling, don't pull the case of the gauge by hand, use a special wrench to install or disassemble.
■To measure oxygen, acetylene or other flammable gases, pressure gauges with oil prohibition signs should be used.
■Please use Hakin special medium pressure gauge when measuring the medium that is explosive or corrosive, easy to crystallize or solidify.
■The pressure gauge should be installed horizontally or vertically.
Model Code
lf you have other requirements, please confirm with our company's technical department before customizing.
Pressure Range & Accuracy
In order to meet the different needs of the measured medium, we have successively developed multiple models based on the original common models, such as shock-resistant, all stainless steel, all stainless steel shock-resistant, with reed switch electric contact, with isolation devices, etc. (Including different series for ammonia, oxygen, temperature resistance, shock resistance, etc.
Size
Demo Mode
★Reed Switch Electric Contact Pressure Gauge, Diameter φ100, Bottom Connected, Pressure Range0~ 1MPa, Connection Thread M20*1.5
If you can provide information such as measuring medium, installation conditions, etc, we can select the model for you more quickly and accurately.
Order Remarks
Safety Warning
For safety, please select the correct model of product. If the product is selected or used improperly, it may cause property loss or personal injury. The designer and user of the system should be fully responsible for selecting the correct product and using the product in the correct way.